What the automated tests check

The test suite (tests/, run with run_tests) analyses synthetic data with known answers, analytic signals and published textbook examples, and compares the results with stated tolerances. Continuous integration runs it in real MATLAB, with a virtual display, on every push.

Scope and limits

Demo ground truth recovered

QuantitySimulated / exactChecked withinTest
LDF: response peak delay (trial average)4 s± 0.5 sDemoDataTest, LDFPipelineTest
LDF: response amplitude30 PU± 25% (DemoDataTest); ± 5 PU (LDFPipelineTest)DemoDataTest, LDFPipelineTest
LDF: onsets and trials9 onsets, 8 complete trialsonsets ± 1 sample; exact countLDFPipelineTest
LDF processing vs the previous in-app codesame trials1e-12LDFPipelineTest
ERP: N1 latency on the sink channel15 ms± 3 msDemoDataTest, LFPFeaturesTest
ERP: channel with the deepest N1; CSD sink channelchannel 4exactDemoDataTest, LFPFeaturesTest
ERP: stimulus onsets15 onsets± 1 sampleLFPFeaturesTest
ERSP: 40 Hz burst, 100–200 ms (oscillation demo)phase-locked burst> 6 dB; ITPC > 0.8; < 3 dB on channel 8LFPFeaturesTest
Band power: theta on channel 8A² = (40 µV)²± 20%, not modulated by the stimuliLFPFeaturesTest
MUA: threshold crossings on channel 4simulated spike count0.6× to 1.5×DemoDataTest
MUA: units after sorting + auto-merge (channel 4)2 home units (+1 from channel 5)2 to 3 unitsMUAFeaturesTest
Imaging: time of the last calcium peak11 s± 0.6 sDemoDataTest
Imaging: mean vessel diameter12 px± 3 pxDemoDataTest
Imaging: red blood cell speed from the kymograph2 px/frame± 0.3DemoDataTest
Motion correction: per-frame shift errorrandom walk, max 3 px< 0.3 px (mean reference), < 0.4 px (first frame)ImagingFeaturesTest
Detect cells3 cellsexactly 3, centres within 3 pxImagingFeaturesTest
ΔF/F per detected cellevent times per cellpeaks ± 0.5 s; < 0.1 at other cells' eventsImagingFeaturesTest
Robust vessel diameter with a crossing blood cell12 ± 3 px sinemax error < 2.5 px, RMS < 1 px (standard: jumps > 10 px)ImagingFeaturesTest
Group demo: paired t-test, Control vs Stimulated+12 PU (population)p < 0.05, CI above 0, dz within 30% of the sample valueStatsFeaturesTest
Batch LDF: latency / amplitude per file3–4.5 s / 20–35 PU± 0.4 s / ± 3 PUBatchFeaturesTest
Batch LFP: N1 latency / amplitude / sink channel12–18 ms / −100 to −140 µV / 3–5± 1.5 ms / ± 20% / exactBatchFeaturesTest
Batch imaging: peak ΔF/F / time / mean diameter0.5–1.5 / known / 10–14 px± 0.1 / ± 0.15 s / ± 0.75 pxBatchFeaturesTest
Batch features: latency / amplitude3–4.5 s / realised mean± 0.35 s / ± 1.5 PUBatchFeaturesTest
Batch MUA: same recording at 2× gainidentical spikesspike count ± 5%; 2–3 units; evoked rate > 3× baselineBatchFeaturesTest
CSD methods (core/demo/demoCSD.m): depth of the sinksink at contact 8 of 16 (4 of 8) at 15 ms; discs 500 µm widewithin one contact for Standard, iCSD delta / step / spline and kCSD; the inverse methods have a lower error than Standard; Standard is bit-identical to the previous CSDCSDFeaturesTest, CSDWalkthroughTest

Analytic checks

FunctionKnown answerTest
Peak latency, amplitude, onset delay (50%), FWHM, rise (10–90%), decay (to 50%), AUCclosed-form values of a Gaussian response on a raised baseline, also mirrored (negative); NaN on empty or flat windowsSignalFeaturesTest
ROI intensity, ΔF/F, movement, kymograph speed (three methods), vessel diametersmall synthetic stacks with exact answersImagingTest
Sub-pixel vessel diametersoft-walled synthetic profiles: error < 0.5 px, better than sample countingImagingFeaturesTest
Hampel filterflags exactly the injected spikesImagingFeaturesTest
Morlet waveletspeak at a 25 Hz sinusoid (± 1 Hz), correct phase, flat power for white noise (± 15%)LFPFeaturesTest
Welch spectrumpeak at 50 Hz; total power = variance (± 2%); white-noise floor 2σ²/fsLFPFeaturesTest
Spectrogramtracks a 10 → 30 Hz change (± 2 Hz)LFPFeaturesTest
Band power|analytic signal|² = A² (± 1%), nothing outside the bandLFPFeaturesTest
CSDV(z) = z² gives CSD = −2 everywhereLFPFeaturesTest
Epoch averagingedge epochs excluded, not zero-filledLFPFeaturesTest
Auto-mergemerges two copies of one unit (r > 0.95); keeps units that differ in size or shapeMUAFeaturesTest
Splitseparates two mixed units (> 97% correct); merge undoes the splitMUAFeaturesTest
PSTHrecovers a 10 → 100 spikes/s step (± 15%)MUAFeaturesTest
Correlogramsempty within the 2 ms dead time; cross-correlogram peak at a known 5.5 ms lagMUAFeaturesTest

Statistics

GroupStats is written in base MATLAB and checked against published textbook results that statistics packages reproduce:

File formats and sessions

Every window, driven step by step

AppSmokeTest opens every window and dialog. The walkthrough tests (DemoWalkthroughTest and the per-area walkthroughs) drive each window through its steps on the demo data through the same public methods the buttons call, save a screenshot after every step (the frames on this site), and fail if a step errors or, for several steps, if the result misses the simulated values.

Examples: simulated vs measured in the screenshots

WhereSimulatedShown in the window
Batch, LDF: peak latency per file3, 3.5, 4, 4.5 s3.06, 3.65, 3.90, 4.47 s
Batch, imaging: peak ΔF/F per file0.5, 1.0, 1.50.504, 1.006, 1.521
Batch, response features: peak latency (mean trace)3, 3.5, 4, 4.5 s3.1, 3.6, 4.1, 4.4 s
MUA: units on channel 4 after auto-merge2 units on channel 4, 1 on channel 53 units (356, 177, 62 spikes); merge r = 0.98
Motion correction: largest shift3 px3.0 px
Groups: Stimulated − Control12 PU (population)11.9 PU [95% CI 9.1, 14.7], p < 0.0001
Estimated rigid shifts (solid) against the true shifts of the advanced demo (dashed).DEMO DATA — synthetic, generated by core/demo/demoImagingAdvanced.m
Estimated rigid shifts (solid) against the true shifts of the advanced demo (dashed).
Robust vessel diameter (green) against the standard estimate (grey), which jumps when the blood cell crosses the line.DEMO DATA — synthetic, generated by core/demo/demoImagingAdvanced.m
Robust vessel diameter (green) against the standard estimate (grey), which jumps when the blood cell crosses the line.